2-52部分 | |
Test Category | |
Protection against patient entrapment in non-moving parts防止病人夹在非活动部位201.9.2.2 | |
Gaps缺口201.9.2.2.3 | Safe distances安全距离 |
Continuous activation不断激活201.9.2.3.1 | |
Instability-overbalances不稳定 | |
Instability excluding transport不稳定不包括运输201.9.4.2.3 | Instabiity from horizontal and vertical forces来自水平和垂直力量的不稳定性 |
201.9.4.2.4.3 | |
Instability in transport运输的不稳定201.9.4.3.2 | |
Grips and other handling devices手柄和其他处理装置201.9.6.2.1 | |
Hazards associated with support systems与支持系统相关的危险201.9.8.1 | |
Tensile safety factory拉伸安全工厂201.9.8.3 | |
Static forces due to loading from persons由于人的负荷而产生的静力201.9.8.3.3 | |
General一般201.9.8.3.3.2 | |
Side rail strength and latch reliability侧轨强度和锁扣可靠性201.9.8.3.3.4 | |
Systems with mechanical protective devices带有机械保护装置的系统201.9.8.4.1 | |
Systems without mechanical protective devices没有机械保护装置的系统201.9.101 | |
Protection against unwanted and excessive radiation Hazards防止不必要的和过量的辐射危害201.11 | |
Maximum temperature during normal use正常使用时的最高温度201.11.6.5 | |
Cleaning and disinfection of ME EQUIPMENT and ME SYSTEMS清洁和消毒ME系统201.11.6.6.101 | |
Interruption of the power supply/SUPPLY MAINS TO ME EQUIPMENT电源供应ME设备的中断201.12 | |
HAZARDOUS SITUATIONS and fault conditions危险情况和故障情况201.14 | |
201.15.3.4.1 | |
Rough handling test野蛮装卸测试201.15.4 | |
201.15.4.4 | Indicators指标 |
201.15.4.7.1 | Mechanical strength机械强度 |
201.15.4.101 | HEAD/FOOT BOARD assembly头/脚踏板总成 |
201.16 | ME SYSTEMS ME系统 |
MEDICAL BED and MOBILE hoists医疗床和移动式升降机的组合 | |
BB.4.3 | Combination of <span style="font-size:9.0pt;font-family:;" "="">MEDICAL BED and mattress医疗床和床垫的结合 |
BB.4.4 | Range of adjustment of moveable sections of the MATTRESS SUPPORT PLATFORM气垫支撑平台可移动部分的调整范围 |
Sample Size: 4
samples for manual beds and 4 set of electric elements for electric
beds;Turnaround Time: 30 working days | |
Remark:need the client
to provide the mattress |
Others 其他信息:
Photo for reference 涉及图片:
Sample Report 报告样本: